HomeStep Up Easily With Your Railway CablesBlogStep Up Easily With Your Railway Cables

Step Up Easily With Your Railway Cables

Home » Blog » Step Up Easily With Your Railway Cables
Step Up Easily With Your Railway Cables

When you tackle the installation of railway cables, you’re aiming for a smooth and reliable setup that keeps trains running on time. Ever wondered why some projects hit snags while others glide through inspections? It often comes down to planning, the right materials, and a few on-site tricks. In this article, you’ll get practical tips to make your next signalling cable install a breeze, from choosing robust cables to nailing your route plan.

What are Railway Cables?

Railway cables carry control and signal data between trackside equipment, signal boxes, and central control rooms. Unlike general power cables, these conductors must preserve signal integrity, resist interference, and survive harsh trackside conditions.

Before you pull cables through ducts, you need to know exactly what’s expected. Signalling lines face harsh environments—mechanical shocks, temperature swings, and even electromagnetic interference (EMI) from nearby power circuits. Nearly 40% of signal-related failures trace back to poor cabling infrastructure. Let’s break down what your cables must deliver.

Signalling Railway Cable Types

Railway cables

Railway signalling cables fall into two main groups (Indoor and Outdoor) as per industry practice:

  • Indoor signalling cables: run inside relay rooms or equipment housings.
  • Outdoor signalling cables: ruggedised for trenches, trackside ducts and wayleaves.

Key Specifications to Check

Here’s what to tick off your spec sheet before placing orders:

  • Insulation materialXLPE (cross-linked polyethylene) or EPR (ethylene propylene rubber) gives top mechanical strength and heat resistance.
  • Flame-retardant grade – must comply with railway safety norms, and halogen-free designs cut toxic smoke in emergencies.
  • EMI shielding – braided armour or foil layers minimise interference from high-voltage lines.
  • Core count & cross-section – pick the right conductor size for track circuits, point machines, or axle counters.

Core count and cross-section table

Core × mm²Typical applicationNotes
6 core × 1.5 mm²Tail cablesSimple point or turnout circuits
12 core × 1.5 mm²Main signalling cableMultiple track or point circuits
Custom up to 36Combined power & data linesUse modular assemblies for ease

For full details on core configurations, see railway signalling cable specifications in Zable Cable.

Planning Cable Routes

A solid route plan smooths approvals and keeps installers safe. You’ll need to gather documents, mark waypoints, and agree on crossing points long before digging starts.

Gathering Approval Documents

You’ll need the right documentation before installation, including route layouts, cable charts, and testing records. All plans should go through testing and approvals as per railway standards to ensure compliance and safety.

Selecting Trenches and Ducts

Your choice of ducting saves headaches later. Keep these pointers in mind:

  • Use rigid ducts in rocky or unstable soil.
  • Separate signalling, power, and communication lines by at least 100 mm in shared trenches.
  • In residential areas, bury ducts 750 mm deep or follow local codes.
  • For track crossings, concrete-filled ducts stop cable deflection and protect against sleeper damage.

Preparing Cables and Connectors

railway signalling cables

With specs set and routes approved, it’s time to prep your gear. Pre-terminated assemblies and pre-tested cables slash installation time and risk.

Using Pre-Terminated Assemblies

Modular cable assemblies with plug-and-play connectors trimmed integration time by 35% in a recent European upgrade, and they’re ready for 5G-grade comms trials. You just uncoil, connect, and secure.

Testing and Inspection

Always test your cables before installation. Check for continuity, insulation, and polarity to catch faults early and avoid costly rework.

Keep detailed records—they’ll save you from costly re-pulls if a fault shows up later.

Laying Cables Effectively

Once trenches are ready and cables pre-checked, focus on smooth installation. Poor technique leads to kinks, stress points, or registration issues down the line.

Trenching Best Practices

Follow best practices for trench preparation, cable protection, and cable separation to prevent stress, damage, or interference down the line.

Cable Separation and Protection

Group cables by function, but give them breathing room:

  • Power cables in one duct, signalling and comms in another
  • Use fire-retardant sleeves where cables cross mechanical barriers
  • Install warning tapes 150 mm above cables before backfilling

Handling Track Crossings

Follow your track crossing plan to the letter:

  1. Excavate with hand tools near sleepers.
  2. Lay concrete-filled ducts at the approved depth.
  3. Seal duct ends to stop water ingress.
    This keeps both staff and signalling gear safe.

Ensuring Safety Compliance

Your work must meet strict railway safety standards to protect passengers and staff. Let’s cover the key items.

Flame-Retardant and Halogen-Free Cables

In a fire scenario, toxic gas is a hidden killer. Halogen-free designs keep smoke and corrosive fumes to a minimum. Make sure your spec calls for the correct fire performance class.

EMI Shielding and Armour

High-voltage traction lines, transformers, and power feeds can induce noise in signalling pairs. Armour or braided shields stop EMI and mechanical damage, reducing maintenance visits and false signals.

Managing Cable Health

Even the best install needs ongoing care. A proactive maintenance plan keeps your signalling network humming.

Regular Inspections and Fault Detection

Routine walks with thermal cameras or TDR (time domain reflectometry) pick up hot spots and faults before they cause delays. For full procedures, check our guide on railway cable fault detection.

Using Cable Management Systems

Bundling, labelling, and routing cables through trays or clips stops tangles and stress points. A good railway cable management system setup means you can trace a problem cable in seconds, not hours.

Select Your Railway Cable Supplier

Choose suppliers with proven approvals and look for documented quality systems and project references.

Zable Cable specialises in railway cables that meet the standards. We offer tailored solutions, from core count to insulation type, backed by technical support.

Our Railway Cables:

  • Withstand heavy loads, constant vibration, and mechanical stress in railway operations.
  • Has low-smoke, halogen-free (LSHF) materials to reduce risks during fire emergencies.
  • Perform under extreme temperatures, UV exposure, and moisture conditions.
  • Minimizes electromagnetic interference, crucial for safe signal transmission.
  • Supports ease of installation, even in complex railway infrastructures.

Final Thoughts

  • Know your cable specs: insulation, flame rating, and EMI shielding matter
  • Plan your route with detailed documents and approved plans
  • Use pre-terminated, pre-tested cables to cut on-site time
  • Follow trenching, separation, and crossing best practices
  • Stick to safety standards for fire and interference protection
  • Schedule inspections and use cable management for long-term health

Frequently Asked Questions

1. What are railway cables made of?

    These cables typically use Class 2 copper or aluminum conductors, insulated with cross-linked polyethylene (XLPE) and shielded with a helical copper or aluminum screen.

    2. How often should cables be inspected?

    Aim for quarterly visual and thermal checks, with a full TDR scan at least once a year. More frequent tests can catch faults before they interrupt service.

    3. How do train cables work?

    A catenary system is a network of overhead wires that supplies electric power to trains. Trains connect to these wires using pantographs, which draw the electricity needed for propulsion as they move along the tracks.

    4. How do you protect against electromagnetic interference?

    Use cables with braided armour or foil shielding. Maintain separation between signalling and power lines in shared trenches or ducts.

    Leave a Reply

    Your email address will not be published. Required fields are marked *

    Seraphinite AcceleratorOptimized by Seraphinite Accelerator
    Turns on site high speed to be attractive for people and search engines.