XLPE Insulated PVC Sheathed Power Cable
The YJV XLPE Insulated PVC Sheathed Power Cable carries medium-voltage power safely. It uses XLPE insulation for better performance, and its resistance to flame using PVC sheath protects it from heat, damage, and harsh environments while maintaining its properties.
- Insulation : XLPE insulation handles high voltages, resists heat, and keeps the electricity flow safe.
- Sheath : Uses a PVC sheath for protection, resistance, and weatherproofing.
- Voltage Rating :Has a rate of 0.6/1 kV for standard medium voltage applications.
- Temperature Range : Works best within a temperature range of -20°C to +90°C.
- Durability :Long-lasting performance in indoor, outdoor, and underground installations; conduit or direct burial.
Technical Product Breakdown
-
Conductor: Copper or Aluminum (depends on the variant).
-
Insulation: XLPE (Cross-Linked Polyethylene).
-
Sheath: PVC (Polyvinyl Chloride).
-
Voltage Rating: 0.6/1 kV.
-
Temperature Range: -20°C to +90°C.
-
Compliance: IEC 60502, BS 6346, and UL 1072.
-
Flame Retardant: Yes (PVC sheath).
Technical Breakdown of Our XLPE Insulated PVC Sheathed Power Cables
- PVC SHEATH:
Provides high protection as the outer sheath. It's strong and holds out against environmental factors like moisture, corrosion, and UV exposure. Perfect for tough outdoor and industrial applications.
- XLPE INSULATION:
Offers durable performance in extreme temperatures with high thermal resistance. Top-quality insulation for safe, accurate, and reliable operation, especially in environments with high voltage and high temperature.
- COPPER CORE TECHNOLOGY:
Copper in XLPE insulated PVC sheathed power cable guarantees exceptional conductivity and reliability using its excellent electrical properties. It is best suited for transmitting efficient power and minimizing energy loss.
- FILLER:
XLPE insulated PVC sheathed power cable uses fillers to maintain the shape and quality of the cable. With consistent strength and flexibility, it protects conductors and insulation layers while enhancing performance.
XLPE Insulated PVC Sheathed Power Cable Collection
|
Model |
Name |
Scope of Use |
|---|---|---|
|
KVV |
Copper Core Polyurethane Insulated Polyurethane Sheathed Control Cable |
Installed in fixed locations requiring shielding, such as indoors, in cable trenches, and in conduits |
|
KVVP |
Copper Core Polyethylene Insulated Polyethylene Sheathed Shielded Control Cable |
Installed in fixed locations requiring shielding, such as indoors, in cable trenches, and in conduits |
|
KVVP2 |
Copper Core Polyurethane Insulated Polyurethane Sheathed Copper Tape Shielded Control Cable |
Installed in fixed locations requiring shielding, such as indoors, in cable trenches, and in conduits |
|
KVV22 |
Copper Core PVC Insulated Polyurethane Sheathed Steel Tape Armored Control Cable |
Installed in fixed locations that can withstand significant mechanical forces, such as indoors, in cable trenches, in conduits, and directly buried |
|
KVVR |
Copper Core PVC Insulated Polyethylene Sheathed Flexible Control Cable |
Installed in indoor locations requiring flexibility for movement and mobility |
|
ZR-KVVRP |
Copper Core PVC Insulated PVC Sheathed Braided Shielded Flexible Control Cable |
Installed in indoor locations requiring flexibility and shielding for movement and mobility |
|
ZR-KVV |
Copper Core PVC Insulated Polyethylene Sheathed Flame-Retardant Control Cable |
Copper Core PVC Insulated Polyethylene Sheathed Flame-Retardant Control Cable |
|
ZR-KVVP |
Copper Core PVC Insulated PVC Sheathed Copper Tape Shielded Flame-Retardant Control Cable |
Installed in fixed locations with flame-retardant requirements, such as indoors, in cable trenches, and in conduits |
|
ZR-KVV |
Copper Core PVC Insulated Polyethylene Sheathed Armored Flame-Retardant Control Cable |
Installed in fixed locations that can withstand significant mechanical forces and have flame-retardant requirements, such as indoors, in cable trenches, in conduits, and directly buried |
|
ZR-KVVR |
PVC Insulated PVC Sheathed Flame-Retardant Flexible Control Cable |
Installed in indoor locations with flame-retardant requirements that allow for mobility and flexibility |
|
WDZ-KYJY |
Copper Core Cross-Linked Polyethylene Insulated Low Smoke Halogen-Free Polyolefin Sheathed Flame-Retardant Control Cable |
Installed in emergency locations such as control and monitoring circuits, fire alarm systems, and emergency access for firefighting equipment |
|
WDZ-KYJYP |
Copper Core Cross-Linked Polyethylene Insulated Low Smoke Halogen-Free Polyolefin Sheathed Copper Wire Braided Shielded Flame-Retardant Control Cable |
Installed in emergency locations such as control and monitoring circuits, fire alarm systems, and emergency access routes for firefighting equipment |
|
WDZ-KYJYP |
Copper Core Cross-Linked Polyethylene Insulated Low Smoke Halogen-Free Polyolefin Sheathed Copper Tape Shielded Non-Flame-Retardant Control Cable |
Installed in emergency locations such as control and monitoring circuits, fire alarm systems, and emergency access routes for firefighting equipment |
|
WDZ-KYJY22 |
Copper Core Cross-Linked Polyethylene Insulated Low Smoke Halogen-Free Polyolefin Sheathed Copper Tape Armored Shielded Flame-Retardant Control Cable |
Installed in emergency locations such as control and monitoring circuits, fire alarm systems, and emergency access routes for firefighting equipment |
|
WDZ-KYJYR |
Copper Core Cross-Linked Polyethylene Insulated Low Smoke Halogen-Free Polyolefin Sheathed Flame-Retardant Flexible Control Cable |
Installed in emergency locations such as control and monitoring circuits, fire alarm systems, and emergency access routes for firefighting equipment |
|
WDZ-KYJYRP |
Copper Core Cross-Linked Polyethylene Insulated Low Smoke Halogen-Free Polyolefin Sheathed Copper Wire Braided Shielded Non-Flame-Retardant Flexible Control Cable |
Installed in emergency locations such as control and monitoring circuits, fire alarm systems, and emergency access routes for firefighting equipment |
Core Functions of the Power Cable
- Power Transmission:
XLPE insulated PVC sheathed power cable is used in industrial, commercial, and residential power distribution systems that use medium voltage power transmission.
- High-Performance Insulation:
Withstands high temperatures with XLPE insulation, along with high electrical and thermal performance.
- Flame Retardant:
The PVC sheath has properties that resist high heat and helps the cable work well in areas with a high risk of fire.
- Protection from External Elements:
XLPE insulated PVC sheathed power cable lasts long in challenging environments with its resistance to UV radiation, moisture, and mechanical stress.
Key Applications and Installation Environments
- Energy Distribution:
Commonly in power plants, substations, and other industrial facilities, this cable distributes medium voltage electrical power where it's needed most.
- Building and Construction:
Used in large buildings or residential complexes for efficient and reliable power distribution.
- Underground Installations:
Buried directly in trenches or installed in ducts for transmitting power underground.
- Outdoor Installations:
XLPE insulated PVC sheathed power cable with weather resistance is used outdoors that gets exposed to moisture, UV rays, physical wear, and other environmental factors.
Create Your Perfect Cable
Armoured Cable
|
Type |
STA (Steel Tape Armored) |
SWA (Steel Wire Armored) |
ATA (Aluminum Tape Armored) |
AWA (Aluminum Wire Armored) |
|---|---|---|---|---|
|
Structure |
Cable wrapped around with 2 layers of steel tape |
A layer or multiple layers of galvanized steel wires. |
Cable wrapped around with 2 layers of aluminum tape |
A layer or multiple layers of galvanized aluminum wires. |
|
Function |
Increases mechanical strength and compressive resistance. Best for direct burial or environments that require high mechanical pressure resistance. |
Provides high tensile strength and mechanical protection. Best for vertical or high-tension installations like bridges or mines. |
Provides corrosion resistance in humid areas and reduces the overall weight of the cable |
Work best as single-core cables to avoid eddy current losses from steel wire armor while offering good corrosion resistance. |
|
Application |
Commonly used in low and medium-voltage power cables. |
Suitable for medium and high-voltage cables in environments that needs strong mechanical protection. |
Used in low-voltage applications where high mechanical strength isn't required, but corrosion resistance matters |
Used for single-core AC power cables, especially in high-current scenarios. |
Product Specifications and Samples
|
Product Name |
Description |
|---|---|
|
YJV22 |
XLPE Insulated PVC Sheathed Steel Tape Armored Power Cable |
|
YJV32 |
XLPE Insulated PVC Sheathed Fine Steel Wire Armored Power Cable |
|
YJV42 |
XLPE Insulated PVC Sheathed Coarse Steel Wire Armored Power Cable |
|
YJY23 |
XLPE Insulated PE Sheathed Steel Tape Armored Power Cable |
|
YJY33 |
XLPE Insulated PE Sheathed Fine Round Steel Wire Armored Power Cable |
|
VV22 |
PVC Insulated & Sheathed Steel Tape Armored Power Cable |
|
VV32 |
PVC Insulated & Sheathed Fine Steel Wire Armored Power Cable |
|
VV42 |
PVC Insulated & Sheathed Coarse Steel Wire Armored Power Cable |
|
KVV22 |
PVC Insulated & Sheathed Steel Tape Armored Control Cable |
|
KYJY22 |
XLPE Insulated PE Sheathed Steel Tape Armored Control Cable |
Fire Resistance Cable Types and Their Characteristics
|
Type |
ZR - Flame Retardant |
NH - Fire Resistance |
Class B1 Fire Resistance |
|---|---|---|---|
|
Definition |
Prevent the spreading of flames, but may lose electrical performance under high heat. |
Keeps the flow of electrical power supply in case of fire for a certain period while vital equipment stays operational. |
High grade fire resistance for the cable to remain functional even under extreme heat. |
|
Resistance Performance |
Maximum service temperature: 90°C. Maximum short-circuit temperature:250°C (max. 5 s). |
Resists fire for 120 minutes at 750°C. |
Resists fire for 180 minutes at 950°C. |
|
Standard |
IEC 60332 & GB/T 18380.3 |
IEC 60331 & GB/T 19216.2 1-2003 |
IEC 60331 & GB/T 19216.2 1-2003 |
|
Applications | Construction: High-rise buildings, residential complexes, and malls. Transportation: Subways, railways, and airports Industrial: Power plants, petrochemical plants, workshops. Data Center:Communication and server facilities |
Used in critical power supply systems like emergency lighting,fire alarms, and other |
Best to use in extreme environments, including high-risk areas like hospitals |
Product Specifications and Samples
|
Product Name |
Description |
|---|---|
|
ZR-YJV |
XLPE Insulated PVC Sheathed Flame Retardant Power Cable |
|
ZR-VV |
PVC Insulated & Sheathed Flame Retardant Power Cable |
|
ZR-YJY |
XLPE Insulated PVC Sheathed Flame Retardant Power cable |
|
NH-VV |
PVC Insulated & Sheathed Fire Resistance Power Cable |
|
NH-YJV |
XLPE Insulated PVC Sheathed Fire Resistance Power Cable |
|
NH-YJY |
XLPE Insulated PE Sheathed Fire Resistance Power Cable |
|
NG-A (BTLY) |
Flexible Mineral Insulated Metal Sheathed Cable with Class A FIre Resistance |
|
BTRY |
Flexible Mineral Insulated Metal Sheathed Cable |
|
Z-GA |
Extreme Class A+ Fire Resistance Cable |
Halogen Free Low Smoke Cable Types
| Type | LSZH (Low Smoke & Zero Halogen) | LS5 (Low Smoke & Standard Halogen) | LSF (Low Smoke Flame Retardant) | LSOH (Low Smoke Zero Halogen) | HFFR (Halogen Free Flame Retardant) |
|---|---|---|---|---|---|
| Structure | Designed with halogen-free materials and a low-smoke, flame-retardant sheath. | Made with materials with standard halogen content and low smoke emission. Used especially when halogen-free is not compulsory. | Features low-smoke, flame-retardant materials for fire-prone environments. | Uses low-smoke, zero halogen materials to reduce the emission of toxic gases and smoke in case of fire situations. | Designed with halogen-free materials and a flame-retardant sheath to reduce smoke and prevent fire hazards. |
| Function | Minimizes toxic smoke and halogen emissions during fire, and boosts fire safety in enclosed spaces. | Reduces smoke and toxic gas emissions, with less emphasis on halogen-free materials. | Provides fire resistance and is often used in environments with moderate fire risk. | Offers high fire safety with no halogen and is best used in confined spaces like tunnels and subways. | Designed to offer halogen-free and flame-retardant materials for industrial facilities. |
| Application | Used in areas like tunnels, subways, and public spaces with high traffic for minimal emissions | Used in places like public buildings where halogen-free materials are not required. | Used in residential buildings, office areas, and other environments where halogen-free is not needed. | Best for high-risk environments like tunnels, subways, and airports where both fire reduction and halogen-free properties are needed. | Used in high safety-risk areas such as hospitals, schools, and data centers where fire resistance and protection are important |
Product Specifications and Samples
| Product Name | Description |
|---|---|
| WD-YJY | XLPE Insulated PE Sheathed Halogen-Free Low Smoke Power Cable |
| WD-KYJY | XLPE Insulated PE Sheathed Halogen-Free Low Smoke Control Cable |
| WD-VV | PVC Insulated PE Sheathed Halogen-Free Low Smoke Power Cable |
Metal Shielded Cable
| Type | MSA (Metal Shielded Cable) |
|---|---|
| Structure | Metal shield wraps around the cable, protecting against electromagnetic interference (EMI) and physical damage. |
| Function | The cable shields from EMI with mechanical strength for stable signal transmission even in harsh environments. |
| Application | Found in control systems, power distribution, and in industrial facilities that have high electromagnetic interference (EMI) |
| Standards | Follows electrical standards such as IEC 60502 and UL 1072 for medium and high-voltage power cables. |
Product Specifications and Samples
| Product Name | Description |
|---|---|
| YJVP | XLPE Insulated PVC Sheathed Metal Shielded Power Cable |
| YJYP | XLPE Insulated PE Sheathed Metal Shielded Power Cable |
| VVP | PVC Insulated & Sheathed Metal Shielded Power Cable |
Aluminium Core Cable
| Type | ACA (Aluminium Core Cable) |
|---|---|
| Structure | Features aluminum conductors instead of copper for reduced weight and expense of cable. |
| Function | Cost-effective solution with lightweight electrical transmission, especially for offering good conductivity in low and medium voltage applications. |
| Application | Used mainly in power distribution, in overhead power lines and long-distance electrical transmission. |
| Standards | Follow the standards; IEC 60502-1 for medium-voltage cables and IEEE 1283 for overhead power lines. |
Product Specifications and Samples
| Product Name | Description |
|---|---|
| YJLV | XLPE Insulated PVC Sheathed Aluminium Core Power Cable |
| VLV | PVC Insulated & Sheathed Aluminium Core Power Cable |
Flexible Cable
| Type | FC (Flexible Cable) |
|---|---|
| Structure | Consist of multiple fine strands of copper or aluminum wire that provide flexibility and ease of movement. |
| Function | Flexible in applications that require frequent bending, movement, or installation in tight spaces |
| Application | Used in machinery, robotics, portable equipment, and power tools, where cables bend or move frequently. |
| Standards | Meets industry standards; IEC 60227 for PVC insulated cables and UL 62 for flexible cables used in portable devices. |
Product Specifications and Samples
| Product Name | Description |
|---|---|
| YJYR | XLPE Insulated PE Sheathed Flexible Power Cable |
| YJVR | XLPE Insulated PVC Sheathed Flexible Power Cable |
| BTRY | Flexible Mineral Insulated Cable |
| RVV | PVC Insulated & Sheathed Flexible Cable |
Place Your Wholesale Order for Power Cables Now!
Why Choose Us?
Innovative Technology
We utilize advanced technology and research to develop high-quality, fire resistant cables and wires for diverse applications.
Sustainable Practices
We are dedicated to environmentally responsible manufacturing, ensuring sustainability through every step of production.
Efficient Production
With streamlined processes, we offer fast turnaround times while maintaining high-quality standards and reliability.
Innovative Technology
Sustainable Practices
Efficient Production
Our Certifications
Hear What Our Clients Say
Frequently Asked Questions
XLPE stands for Cross-Linked Polyethylene and PVC is Polyvinyl Chloride.
XLPE is used as the insulation material due to its excellent thermal resistance, durability, and electrical properties, making it ideal for high-voltage applications.
PVC is used as the outer sheath, providing flexibility, flame resistance, and protection against moisture, UV rays, and mechanical wear.
This cable is an electrical cable and it is used for high-voltage power transmission and distribution.
The XLPE offers excellent insulation, resists heat, and offers long-lasting performance in various applications.
The cable effectively operates within a temperature range of -20°C to +90°C.
You can install it indoors and outdoors. You can either bury it directly in the ground or run it through a conduit.
Yes, XLPE Insulated PVC Sheathed Power Cable is flame retardant. It provides safety and stops the spread of fire.
We offer a standard lead time for orders, which is approximately 15 days. This may vary depending on the requirements of your order. But still, we will make sure to deliver them on time without delays.
We offer in-stock products as well as custom-made options. Choose from our available stock or request customization of your products according to your preferences.
The customization offered will be based on cable models and specifications for your local area. We’ll work with you and offer products that meet your exact needs and specifications.